High Temperature Hydrogen Attack

High temperature hydrogen attack | TÜV Rheinland

Detect, assess and evaluate harmful high temperature hydrogen attacks with our non-destructive services

Productive and profitable industrial plants rely on intact and reliable equipment to sustain expected production levels and quality standards. Due to the presence of hydrogen, in combination with high temperature and pressure, the phenomenon of a high temperature hydrogen attack (HTHA) can occur within vessels and piping, making plants and systems susceptible to damage. As a result, this reaction can cause an industrial plant to suffer serious failure, which may lead to both expensive repairs and loss of production.

Our experts perform advanced non-destructive high temperature hydrogen attack (HTHA) testing services to ensure your critical equipment is in good condition and working to its utmost potential. A series of procedures has been developed featuring the latest advances in ultrasonic imaging and data processing techniques in order to achieve a greater level of confidence in both HTHA inspection results and inspection repeatability. Know the status of your assets to ensure the efficient and effective operation of your plant or factory.

With a deep understanding of both the HTHA phenomena and the methods of assessment, our experienced technicians evaluate the presence of hydrogen damage to prevent failure and minimize your risk.

Speak with an expert today to find out how we can help you detect, assess and monitor attacks on your critical equipment!

Protect equipment and gain competitive edge with reliable HTHA results

Our global network of experts helps you maintain the integrity of your assets to ensure uninterrupted productivity. We implement state-of-the-art digital techniques to detect HTHA with high reliability and reproducibility. We provide clear results according to our excellent processing procedures. Our trained technicians are able to examine numerous different geometries such as vessels and piping and accurately monitor damage progress with repeated inspections to ensure all kinds of equipment are in safe working order. We provide comprehensive HTHA services from a single source to save you both time and money.

Our HTHA inspection in accordance with API 941 guidelines

High temperature hydrogen attack (HTHA) can cause serious damage such as decarburization and micro-cracking in steels exposed hydrogen at elevated temperatures and high pressure. Such damage can negatively affect tensile strength and toughness and ultimately cause failure without warning. Our comprehensive testing provides you reliable results to detect, asses and monitor HTHA and its repercussions.

Our testing techniques

Our comprehensive HTHA testing services include backscatter and velocity time ratio measurement (VTRM) to inspect the parent material and Time of Flight Diffraction (TOFD) to examine weld material as well as further evaluate and characterize suspect damage. Phased array can be used for detection of cracking in nozzle welds.

Inspection techniques for high temperature hydrogen attacks | TÜV Rheinland

Our testing strategies

Industry codes and standards rely on guidelines set by the American Petroleum Institute (API) and its Recommended Practice 941. Developed from industry experience, Nelson curves are used to determine the safe operating limits of temperature and hydrogen partial pressure for susceptible equipment and materials in industrial environments.

Our testing strategies determine suspectability, define the amount of inspection coverage and determine appropriate testing methods:

  • High susceptibility – operating conditions at or above Nelson curves
    • heavy inspection coverage
    • backscatter mapping, velocity ratio measurement, TOFD, 45° shear wave inspection PA, replica’s

  • Medium susceptibility – operating conditions up to 25°F below Nelson curves
    • medium inspection coverage
    • backscatter mapping, manual testing, velocity ratio measurement, TOFD, 45° manual (no need to open vessel)

  • Low susceptibility – operating conditions up to 50°F below the Nelson curves
    • Light inspection coverage
    • Manual backscatter, TOFD

Specialized in proving a complete range of non-destructive testing services

A global leader in independent inspection services, we provide you one-stop-shop services to protect you against harmful HTHA damage. Our qualified specialists are experienced in every industrial segment from power generation to projects in the defense, manufacturing, chemical and petrochemical industries. We provide you the latest and best technologies available today. Take advantage of our expertise to keep you up and running and able to better serve your customers.

Put our HTHA experts to work for you today!

Contact

Contact us to request a non-binding offer

Contact us to request a non-binding offer

Get in contact with us!

This might also interest you

Maintenance and Materials Testing

Maintenance and Materials Testing

Putting Plants and Components to the Test.

discover more

Phased Array Weld Examination

Phased array inspection | TÜV Rheinland

We assess component quality and potential risk with advanced phased array ultrasonic (PAUT) inspection.

discover more

Time of Flight Diffraction Technique for Weld Inspection

Non-destructive weld testing through TOFD

Ensure the integrity of your welded structure.

discover more

Last Visited Service Pages