current language
Japan available in the following languages:
or select your TÜV Rheinland region / country website:
Choose country/ region and language

Thermal Shock · Temperature-Humidity Testing

GTAC TUV Rheinland

The safety and durability of products can be evaluated by simulating the stress of changes in temperature and humidity in a chamber, whose temperature and humidity can be changed freely.

Testing equipment at GTAC

Introduction of some of the equipments at GTAC

Testing chambers TUV Rheinland

Temperature and humidity testing chambers

Temperature: -70℃~+150℃

Humidity: ~98%RH

Dimensions: w600mm × h850mm × d600mm

Testing equipment at GTAC TUV Rheinland

Temperature: -40℃~+150℃

Humidity: ~98%RH

Dimensions: w500mm × h350mm × d350mm

GTAC TUV Rheinland
Thermal Shock Tester TUV Rheinland

Thermal shock tester (with a 2-zone chamber)

High temperature: +150 max.

Low temperature: -50 max.

Time to move items between the two rooms: 0 to 5 sec.

Dimensions: w550mm × h550mm × d550mm

Max. sample weight: 50 kg

Related standards

IEC 60068-2-33, IEC 60068-2-14, ISO 7459 (Thermal shock testing)

IEC 60068-2 series (Temperature testing, temperature-humidity cycling tests and other)

Contact